Troubleshooting■>■Startup■System■Failure■Diagnosis■>■Procedure■A:■Detailed■Procedure■of■Startup■System■Failure■Diagnosis
Troubleshooting■>■Startup■System■Failure■Diagnosis■>■Procedure■A:■Detailed■Procedure■of■Startup■System■Failure■Diagnosis
Procedure■A:■Detailed■Procedure■of■Startup■System■
Failure■Diagnosis
1.■Perform■the■following■checks■if■the■failure■diagnosis■does■not■start.■If■it■starts,■proceed■
to■the■next■step.
•■ Interchange■the■DIMMs■on■the■Main■Controller■1
•■ Install■the■system■software■(Download■by■2+8■startup)
•■ Replace■the■Main■Controller■PCB1
•■ Replace■the■HDD.
•■ Replace■the■Main■Controller■PCB2
2.■When■the■detected■location■is■displayed■on■the■screen■where■"NG"■is■displayed,■
identify■the■location■of■the■failure■by■referencing■the■controller■system■failure■diagnosis,■
and■perform■the■remedy.■If■the■diagnosis■does■not■proceed■to■a■status■where■"NG"■is■
displayed,■proceed■to■the■next■step.
3.■If■the■failure■diagnosis■does■not■finish,■perform■the■following■work:
•■ Install■the■system■software■(Download■by■2+8■startup)
•■ Replace■the■HDD.
•■ Replace■the■Main■Controller■PCB1
•■ Replace■the■Main■Controller■PCB2
•■ Replace■the■DIMMs■on■the■Main■Controller■1■(iR-ADV■C5000■series)