Service Mode > COPIER > OPTION > USER
Service Mode > COPIER > OPTION > USER
COPIER > OPTION > USER
LDAP-SW
Search condition set for LDAP server
Lv.1 Details
To set the condition to search e-mail address, etc. from LDAP server.
Use case
When specifying condition to search e-mail address, etc. from LDAP
server
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 5
0: Includes the next, 1: Not include the next, 2: Equivalent to the
next, 3: Not equivalent to the next, 4: Starts with the next, 5: Finishes
with the next
Default value
4
FROM-OF
Deletion of e-mail sender’s address
Lv.1 Details
To set whether to delete the sender’s address (From) at the time of
e-mail transmission.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Retained, 1: Deleted
Default value
0
DOM-ADD
Additional entry of e-mail destn domain
Lv.2 Details
To set to automatically add the domain specified in user mode to the
sending address (To) entered at the time of e-mail transmission.
If specifying “xxx.com” as a domain in user mode in advance, just
entering “aaa” enables to display “[email protected]” when sending
e-mail.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Not added, 1: Added
Default value
0
SPEAKER
Dis/hide to switch speaker/headphone
Lv.1 Details
[Not used] To set whether to display or hide “Voice Guidance from
Speaker” on the Voice Mode Setting screen in user mode.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
0
Related user mode
Settings/Registration> Preferences> Accessibility> Voice Mode
Setting> Voice Guidance from Speaker
Supplement/memo
“Voice Mode Setting” in user mode is displayed only when the Voice
Guidance Kit is installed.
COPIER > OPTION > USER
FILE-OF
File send prohibition to entered address
Lv.1 Details
To set to prohibit the file transmission to entered address.
File transmission is not available by entering the address because of
no “File” display on the transmission screen.
The addresses already registered in the Address Book can be
selected, but even if a job is sent, it is to be a transmission error. (End
code #762 is displayed.)
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- The addresses already registered in the Address Book can be
selected, but it is to be a transmission error. Therefore, be sure to
receive approval from the user in advance to delete the address. Set
the transmission prohibition after deleting the address.
- When #762 is displayed without executing the procedure above,
explain the user that it is different from the description in the User’s
Guide.
Display/adj/set range
0 to 1
0: Enabled, 1: Disabled
Default value
0
MAIL-OF
Mail send prohibition to entered address
Lv.1 Details
To set to prohibit the e-mail transmission to entered address.
E-mail transmission is not available by entering the address because
of no “E-Mail” display on the transmission screen.
The addresses already registered in the Address Book can be
selected, but even if a job is sent, it is to be a transmission error. (End
code #762 is displayed.)
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- The addresses already registered in the Address Book can be
selected, but it is to be a transmission error. Therefore, be sure to
receive approval from the user in advance to delete the address. Set
the transmission prohibition after deleting the address.
- When #762 is displayed without executing the procedure above,
explain the user that it is different from the description in the User’s
Guide.
Display/adj/set range
0 to 1
0: Enabled, 1: Disabled
Default value
0