6
6
6-69
6-69
Troubleshooting■>■Version■upgrade■>■Version■Upgrade■via■SST■>■Backup
Troubleshooting■>■Version■upgrade■>■Version■Upgrade■via■SST■>■Backup
■
●
Steps■to■Upload■Data
CAUTION:
•■ When■the■Canon■quality-appointed■staff■determines■the■need■for■an■analysis■of■
debug■log■by■the■R&D■department,■we■ask■the■field■to■collect■log■for■an■investigation■
to■determine■the■cause.■
•■ The■backup■data■can■be■downloaded■only■on■the■machine■from■which■the■data■were■
uploaded.
•■ This■machine■does■not■use■SramRCON■and■SramDcon
Service PC
Main controller
Main controller PCB1
iR ----
MeapBack
/ SramImg.bin
SST
HDD
Meapback.bin
System
Upload/Download
iR ADVNCE C5051 Series
Main controller PCB2
SRAM
SramImg.bin
F-6-88
■
●
Listed■below■are■the■sample■steps■to■upload■MeapBack.
1)■Enter■Download■mode.
2)■Connect■the■PC■to■the■machine■to■start■SST.
3)■Select■the■model■to■be■connected■and■“Single”.■Check■the■network■settings■and■click■“Start”.
4)■Click■“Upload■Data”■button.
F-6-89
F-6-90