4
4
4-112
4-112
Parts Replacement and Cleaning > Image Formation System > Removing the Process Unit > Procedure
Parts Replacement and Cleaning > Image Formation System > Removing the Process Unit > Procedure
Removing the Process Unit
■
Preparations
1) Open the Front Cover.
2) Open the Right Lower Cover and Right Upper Cover.
3) Remove the ITB Cover.
4) Pull out the Process Unit.
■
Procedure
CAUTION:
When installing/removing the Process Unit, do not remove the Recycle Toner Bottle.
1) Remove the 4 stepped screws fixed on the right and left rails.
x4
2) Hold the front and rear of Process Unit and remove it flatly.
F-4-168
F-4-169
3) Place the paper onto the Process Unit to protect the Drum Unit from the light.
Paper
4) Take the 2 rails of Process Unit back to the host machine.
NOTE:
When installing the Process Unit, if the Dustproof Shutter is opened and blocks to install
the unit, turn ON and then OFF the power. Be sure to check that the Dustproof Shutter
is closed before installation.