CAUTION:
At installation, avoid the harness, hold the grip in raised condition, put the Main
Controller PCB 2 all the way in, tilt the grip, and install it.
x2
Grip
NOTE:
• If the FAX Unit is installed, install the connector.
• Make sure that the Main Controller PCB 2 is fixed to the device.
■
Actions after Replacement
Turn ON the power and execute the following service mode to restore the data in SRAM.
If Lev1 COPIER > FUNCTION > SYSTEM > DOWNLOAD > OK > [5] BACKUP has
been executed before replacement, execute Lev1 COPIER > FUNCTION > SYSTEM >
DOWNLOAD > OK > [8] Download Menu 2 > [2] Restore.
●
If the machine has the HDD Encryption Board
1) Execute the following in remote UI to restore the backup data.
Management Settings > Data Management > Import/Export
2) Specify and register the data again.
See the list of Settings/Registration data that was printed before replacement, and then
specify and register the data once again.
3) When an encryption key/certificate/CA certificate has been generated or added by the user,
ask the user to execute reinstallation.
CAUTION:
Do not transfer the following parts to another model (which has a different serial
number).
If you fail to do so, the Main Body does not activate normally and this might cause to fail
the restoration.
• Main Controller PCB 2 (with Memory PCB installed)