4
4
4-135
4-135
Parts Replacement and Cleaning > Image Formation System > Removing the Hopper (Y) > Procedure
Parts Replacement and Cleaning > Image Formation System > Removing the Hopper (Y) > Procedure
3) Remove the Left Middle Stay.
• 2 screws
x2
4) While avoiding the duct sheet, remove the Hopper Unit.
• 1 connector
• 1 wire saddle
• 5 screws (RS)
x2
x3
Connector
Hopper Unit
Wire saddle
Duct sheet
F-4-245
F-4-246
CAUTION:
If it is placed sideways, toner may scatter inside the Hopper and it may cause the
operation failure. Thus, stand and put the Hopper Unit on the paper.
Paper
F-4-247
CAUTION:
When installing the Hopper, align the cut-off [A] part of Bottle Fixing Ring with the Bottle
Fixing Arm [B] and install it to the host machine.
[A]
[B]
F-4-248