6
6
6-33
6-33
Troubleshooting■>■Startup■System■Failure■Diagnosis■>■Flow■F:■Connector■Disconnection■Flow■>■Status■Check
Troubleshooting■>■Startup■System■Failure■Diagnosis■>■Flow■F:■Connector■Disconnection■Flow■>■Status■Check
Flow■F:■Connector■Disconnection■Flow
■
■
Status■Check
At■the■time■of■startup,■the■LEDs■of■Main■Controller■1■and■2■turn■ON■and■the■Main■Controller■
Fan■rotates,■but■it■stops■immediately.
■
●
Flow■for■narrowing■down■troubles
Flow E:
From 12V Power Supply System Flow
Open the front door
Note:
Disable the operation of the host machine
Check whether
the 12V Power Supply starts
by disconnecting the connectors of the
Relay PCB in order
Yes
Check the destination short circuit
of the narrowed-down connectors
(harnesses and PCB)
* e.g.
If 12V starts when the DC Controller connector is disconnected
Disconnect the connector of the DC Controller PCB in order and identify the location of failure
Replace the 12V Power Supply
No
F-6-33
■
●
Check■item
1.■If■the■problem■remains■unsolved■even■after■checking■the■short■circuit■of■the■harnesses,■
disconnect■the■following■connector■one■by■one■and■repeat■the■following■procedure■to■check■
whether■the■symptoms■change.
1-a.■Open■the■front■door.■(Disable■the■operation■of■the■host■machine)
1-b.■Check■whether■the■12V■Power■Supply■starts■by■disconnecting■the■appropriate■
connectors■of■the■Relay■PCB.
J451
SO■DCDC■PCB
If■the■12V■Power■Supply■starts■with■the■SO■DCDC■PCB■
(J451)■disconnected,
•■ There■may■be■some■problem■with■DC■Controller,■Hanso,■
or■DrumDrive.
•■ Cables■of■DC■Controller■(J118■and■J119-LS■Harnesses)■
may■be■trapped■or■an■Laser■Scanner■failure■may■have■
occurred.
J422
DC■Controller
J423
HansoDriver■PCB
J424
DrumDriver■PCB
J425
High■voltage■PCB
J426
Reader■ADF■Unit
J427
UI,■USB■Device■Port
1-c.■If■12V■Power■Supply■does■not■start■even■if■disconnecting■and■connecting■the■
connector,■replace■the■12V■Power■Supply.
2.■Check■the■destination■short■circuit■of■the■narrowed-down■connectors■(harnesses■and■PCB).
e.g.
If■12V■starts■when■the■DC■Controller■connector■is■disconnected,
disconnect■the■connector■of■the■DC■Controller■PCB■in■order■and■identify■the■problem.
T-6-17