9210
– 7 –
4344-7741-01
■
Checking for Registration
■
Adjusting Registration
1. Prepare a test chart (A3) as shown.
*
Draw a straight reference line at a point 20
mm from the rear edge and another at a
point 20 mm from the top edge of the chart.
1166U014AA
20mm
20mm
2. Load the test chart in the ADF and make a
full-size copy.
4344U021AA
3. Check that the margins reproduced on the
copy meet the following specifications.
Margin Registration Specifications:
Width A: 20 ± 2.0 mm
Width B: 20 ± 3.0 mm
If the margins reproduced on the copy fall
outside the specified range, make the
“Registration Adjustment.”
1166U015AA
1. Call the Tech. Rep. Mode to the screen.
(See the Service Manual for the procedure.)
4348P005CB
2. Touch “Tech. Rep. Choice.”
4348P005CB
3. Touch “Sheet-through-ADF.”
4348P011CB
4. Touch “Feed (CD)” or “Feed (FD).”
4344P004CA