9218
– 6 –
4348-7743-03
■
Adjusting the Paper Reference Position
6. Touch “3rd Drawer.” (This highlights the “3rd
Drawer” key.)
4348P017CA
7. Press the Start key on the control panel.
(The copier will produce an output of a test
print.)
4002O280CB
8. Measure width A on the test print and check
to see if the measured dimension falls within
the specified range.
<Specifications: 10 ± 2.0 mm>
4348U054AA
A
9. If the measured width A falls within the
specified range, press the Panel Reset key
to recall the Basic screen.
10. If the measured width A falls outside the
specified range, perform the following
procedure to adjust the paper reference
position.
1. Touch “END” on the Test Print screen.
4348P017CA
2. Select “3rd Drawer” on the Registration (CD)
screen. (This highlights the “3rd Drawer”
key.)
4348P015CA
3. Press the Clear (C) key and, using the 10-
Key Pad, change the setting value as
detailed below.
•
If width A is greater than the specified value
(e.g. +1.0 mm), enter -1.0.
•
If width A is smaller than the specified value
(e.g. -1.0 mm), enter +1.0.
*
Press the “
✽
” key to select or -.
4348U093CA