TeraStation User Manual
70
UPS Settings
An UPS (Uninterruptible Power Supply) can protect the TeraStation from power outages and brownouts. To use the
TeraStation with a UPS, proceed as follows:
1
Plug the power cable of the UPS to a wall socket.
2
Connect the AC cable of the TeraStation to the UPS.
3
Connect the UPS to the TeraStation with a USB or serial connection.
Note:
• TS-XEL series TeraStations do not have UPS Port.
4
Turn on the UPS, then the TeraStation.
5
In Settings, click
System
-
Power Management
-
UPS Settings
.
6
Click
Modify Settings
.
7
Notes:
• If the UPS has shut down the TeraStation because of a power outage, make sure that power has been restored before
restarting the TeraStation. If the TeraStation is restarted after a shutdown, but power is not available, then the UPS will
not shut down the TeraStation a second time even if its battery is running low.
• If the TeraStation is set to use UPS recovery, then the UPS will restart the TeraStation when normal power is restored.
1
Configure the desired settings.
If your TeraStation is connected directly to the UPS, select
synchronize
with UPS connected to this TeraStation
. To have the UPS shut down
multiple TeraStations on the same network, select
synchronize with UPS
connected to other TeraStation on the network
and enter the IP address of
the TeraStation that is connected directly to the UPS in the field below.
2
Click
Save
.