System - Power Management
UPS Settings
Click
Modify Settings
to change settings.
Synchronization with
UPS
synchronize with UPS connected to this TeraStation
:
Select to synchronize the TeraStation with a UPS that is directly connected.
synchronize with UPS connected to other TeraStation on the network
:
Select to synchronize the TeraStation with a UPS that is connected to a different
TeraStation on the same network.
do not synchronize with UPS
:
Select if synchronizing to a UPS is not desired.
Synchronized source
TeraStation IP
Address
If
synchronize with UPS connected to other TeraStation on the network
is selected,
enter the IP address of the TeraStation that is directly connected to the UPS.
UPS Connection Type
Select a connection method with UPS.
*
USB Port (APC Style)
or
USB Port (OMRON Style)
can be set only when you are
using USB type UPS manufactured by APC.
* The items to select will vary depending on a UPS model number and a cable.
Refer to Buffalo’s website (www.buffalotech.com) for details.
TeraStation behavior
When Power failure
Allows you to set the time until shutdown when the power failure continues.
Or, you can set to
Shutdown TeraStation when UPS Reports ‘Battery Low’ status.
.
* “Low Battery“ shutdown is only supported with UPSs that are connected to
the TeraStation via USB.
UPS Behavior After
TeraStation has shut
down
Specifies whether shutting down UPS or not after shutting down the
TeraStation.
UPS Recovery
function
Reboot the TeraStation Automatically after recovering supply from AC power
to UPS.
SleepTimer
Click
Modify Settings
to change settings.
Timer Interval
Select Timer Interval from
Disable
,
Everyday
, or
Specific day of the week
for Sleep
Timer.
If selecting
Specific day of the week
, specify the day by tick the box for that day.
Timer can be set up to 3 (1-3).
Wake up at
Specify a wake-up time for the TeraStation to recover from sleep mode and
resume its normal state. Times from 0:00 to 23:45 are allowed.
Begin Sleep at
Specify a time for the TeraStation to move from its normal functionality to a
standby state (sleep mode). Times from 0:00 to 27:45 are allowed.
* Note: The wake-up time must be later than the beginning time.