3522.5-0000010 OM
312
Table 7.2
Error
code
Description, anticipated
problem
Failure inspection method
Complex defects
11
Failure in the electro-
magnetic lift valve control
circuit. Break in the sole-
noid coil 9
(
Figure 3.19.1
)
or in solenoid control ca-
ble
Disconnect the cable from the solenoid and test the
solenoid with a testing apparatus to detect a break. So-
lenoid resistance shall not exceed 2...4 Ohm. In case
the solenoid failure is not detected check the solenoid
control cable for mechanical damage, and check the
wire with the testing apparatus to detect if there is a
break between the solenoid socket terminal and the
terminal 2 of 25-pole socket of the electronic unit
(
Fig-
ures 7.2.1, 7.2.2, 7.2.3)
12
Failure in the electro-
magnetic lowering valve
control circuit. Break in
the solenoid coil 8
(
Figure
3.19.1
)
or in solenoid
control cable
Disconnect the cable from the solenoid and test the
solenoid with a testing apparatus to detect a break. So-
lenoid resistance shall not exceed 2...4 Ohm. In case
the solenoid failure is not detected check the solenoid
control cable for mechanical damage, and check the
wire with the testing apparatus to detect if there is a
break between the solenoid socket terminal and the
terminal 14 of 25-pole socket of the electronic unit
(
Figures 7.2.1, 7.2.2, 7.2.3)
13
Failure in the electro-
magnetic lowering valve
or lift valve control circuit.
Short circuit in one of the
solenoids or short circuit
of the solenoids control
wires in the cable
(
Figure
3.19.1
)
Disconnect the cable from the solenoid and test the
solenoid with a testing apparatus to detect a short cir-
cuit. Solenoid resistance shall not exceed 2...4 Ohm.
Or measure the solenoid useful current applying the
current of 6 V. The current shall not exceed 3.2A. Dis-
connect the socket from the electronic unit, check the
terminals 2 and 14 for a short circuit (the solenoids
shall be disconnected during this procedure)
(
Figures
7.2.1, 7.2.2, 7.2.3)
14
Failure in remote control
buttons for lift 4 (Figure
2.14.2
)
. Short circuit of
wires or sticking of a re-
mote control buttons for
lift
Check the remote control buttons cables for mechani-
cal damage by lift of RLL. Disable each button for lift
one-by-one until the failure is gone. Stop the engine
when you disable the buttons. If the failure is still not
eliminated, disconnect the socket from the electronic
unit and ring out the terminals 10 and 12 for a short
circuit by testing apparatus
(
Figures 7.2.1, 7. 2.2,
7.2.3)
15
Failure in remote control
buttons for lowering 3
(Figure 2.14.2
)
. Short cir-
cuit of wires or sticking of
a remote control buttons
for lowering
Check the remote control buttons cables for mechani-
cal damage by lift of RLL. Disable each button for lift
one-by-one until the failure is gone. Stop the engine
when you disable the buttons. If the failure is still not
eliminated, disconnect the socket from the electronic
unit and ring out the terminals 20 and 12 for a short
circuit by testing apparatus
(
Figures 7.12.1, 7.12.2,
7.12.3)
https://tractormanualz.com/
Summary of Contents for 3522.5
Page 1: ...BELARUS 3522 5 3522 5 0000010 OM OPERATOR S MANUAL 2011 https tractormanualz com ...
Page 9: ...3522 5 0000010 РЭ 10 https tractormanualz com ...
Page 335: ...3522 5 0000010 OM 336 Service bulletins https tractormanualz com ...
Page 337: ...3522 5 0000010 OM 375 Annex B compulsory https tractormanualz com ...
Page 338: ...3522 5 0000010 OM 376 Annex B obligatory https tractormanualz com ...
Page 339: ...3522 5 0000010 OM 377 Annex C obligatory https tractormanualz com ...
Page 340: ...3522 5 0000010 РЭ Annex D obligatory 378 https tractormanualz com ...