3522.5-0000010
РЭ
178
3. Start the engine. Lift up the handle 1 of lift linkage control (figure 3.16.5), when
this happens annunciatior 2 of FLL uplift should shine redly. At the end of uplift the an-
nunciator 2 should go out. In maximal raised position of FLL is allowed reflector zone value
of cylinder rod between 1 and 10 mm. If at maximal raised position cylinder rods are ex-
tended for more than 10 mm, it is necessary to turn additionally the position sensor by
small angle contraclockwise. If cylinder rods are fully retracted, but the annunciator 2 is
lightening, turn the sensor clockwise. Repeat the operation ¨lowering/uplift¨. If the value of
reflected zone of cylinder rod corresponds to above mentioned requirements, fix position
sensor in adjusted position, turning against the stop screws 3(figure 3.16.13).
1 – handle to control lift linkage; 2 – annunciator of FLL uplift.
Figure 3.16.15 – FLL control panel
4. Check correct adjustment of position sensor by lifting and lowering of front lift
linkage several times. Annunciator of uplifting should go out in extreme lifted-up position of
FLL, cylinder rods are almost retracted (reflected zone value between 1 and 10 mm). After
the end of control, place protective cap 2 (figure 3.16.16), turning four screws 1.
1 – screw; 2 – protective cap.
Figure 3.16.16 – Installation of protective cap on FLL position sensor
https://tractormanualz.com/
Summary of Contents for 3522.5
Page 1: ...BELARUS 3522 5 3522 5 0000010 OM OPERATOR S MANUAL 2011 https tractormanualz com ...
Page 9: ...3522 5 0000010 РЭ 10 https tractormanualz com ...
Page 335: ...3522 5 0000010 OM 336 Service bulletins https tractormanualz com ...
Page 337: ...3522 5 0000010 OM 375 Annex B compulsory https tractormanualz com ...
Page 338: ...3522 5 0000010 OM 376 Annex B obligatory https tractormanualz com ...
Page 339: ...3522 5 0000010 OM 377 Annex C obligatory https tractormanualz com ...
Page 340: ...3522 5 0000010 РЭ Annex D obligatory 378 https tractormanualz com ...