Technical data • Individual components
Chapter 2
Technical data
Automation PC 810 with GM45 CPU board user's manual V1.28
137
3.6.15 5ACPCI.RAIC-05
3.6.15.1 General information
This SATA RAID controller supports RAID level 0 and 1 and can be inserted in a PCI slot. The 250 GB hard disks
that are used are specified for 24-hour operation (24x7).
•
SATA RAID controller
•
RAID Level 0 (striped) and 1 (mirrored)
•
2 SATA hard disk drives (suitable for 24 hour operation)
•
Only requires 1 PCI slot
•
Transfer rates up to 150 MB/s
Primary Hard Disk (HDD 0)
Secondary Hard Disk (HDD 1)
HDD 0
HDD 1
SATA
RAID
Access LED (yellow) for primary (HDD 0)
and secondary hard disk (HDD 1)
Figure 55: PCI SATA RAID controller
Information:
The PCI SATA RAID controller cannot be used in place of a Universal Power Supply (UPS). If the oper-
ating system is shut down improperly, the next time it is started it is detected as an error by the RAID
1, and a complete rebuild is executed. With a memory size of 250 GB, this generally takes at least 250
minutes to complete (configurable).
3.6.15.2 Order data
Model number
Short description
Figure
Drives
5ACPCI.RAIC-05
PCI RAID System SATA 2x 250 GB; Remark: Please see man-
ual for proper use of the hard disk.
Optional accessories
Drives
5MMHDD.0250-00
250 GB SATA hard disk replacement for 5AC801.HDDI-03 and
5ACPCI.RAIC-05; Remark: Please see manual for proper use
of the hard disk.
Table 85: 5ACPCI.RAIC-05 - Order data