Accessories • Uninterruptible power supply
Chapter 6 Accessories
Automation PC 810 with GM45 CPU board user's manual V1.28
335
9.3 5AC600.UPSI-00
9.3.1 General information
The add-on UPS module can easily be installed in an appropriate system unit (List of required revisions: see section
9.2 "Requirements" on page 334).
9.3.2 Order data
Model number
Short description
Figure
Uninterruptible power supplies
5AC600.UPSI-00
UPS module for APC620, APC810, PPC800; for system
units 5PC600.SX01-00 (from Rev. H0), 5PC600.SX02-00
(from Rev. G0), 5PC600.SX02-01 (from Rev. H0),
5PC600.SX05-00 (from Rev. F0), 5PC600.SX05-01 (from
Rev. F0), 5PC600.SF03-00 (from Rev. A0), 5PC810.SX*.
5PC820.1505-00, 5PC820.1906-00. Cable (5CAUPS.0005-00
or 5CAUPS.0030-00) and battery unit (5AC600.UPSB-00) have
to be ordered separately.
Required accessories
Uninterruptible power supplies
5AC600.UPSB-00
Battery unit 5Ah; for APC620, APC800 or PPC800 UPS.
5CAUPS.0005-00
UPS cable 0.5 m; for UPS 5AC600.UPSI-00.
5CAUPS.0030-00
UPS cable 3 m; for UPS 5AC600.UPSI-00.
Table 261: 5AC600.UPSI-00 - Order data
9.3.3 Technical data
Information:
The following characteristics, features and limit values only apply to this accessory and can deviate
from those specified for the fully assembled device. The data specifications for the fully assembled
device take precedence over those of individual components.
Product ID
5AC600.UPSI-00
General information
Certification
CE
Yes
cULus
Yes
GL
Yes
Electrical characteristics
Power consumption
Max. 7.5 watts
Power failure bypass
max. 20 min bei 150 W Last
Deep discharge protection
Yes, at 10 V on the battery unit
Short circuit protection
No
Battery charging data
Charging current
Max. 0.5 A
Switching threshold
Battery operation
13 V
Mains operation
15 V
Recommendations
Specified standard
CE (CE)
Yes
UL 508 (cULus)
LISTED 14F2 BR
GL (GL)
Cat. C EMC 1
Recommendations
Specified standard
CE (CE)
Yes
UL 508 (cULus)
LISTED 14F2 BR
GL (GL)
Cat. C EMC 1
Table 262: 5AC600.UPSI-00 - Technical data
9.3.4 Installation
This module is installed using the materials included in delivery. For more information regarding installation, see