Technical data • Individual components
140
Automation PC 810 with GM45 CPU board user's manual V1.28
3.6.16 5ACPCI.RAIC-06
3.6.16.1 General information
This SATA RAID controller supports RAID level 0 and 1 and can be inserted in a PCI slot. The 500 GB hard disks
that are used are specified for 24-hour operation (24x7).
•
SATA RAID controller
•
RAID Level 0 (striped) and 1 (mirrored)
•
2x 500 GB SATA hard disks (suitable 24 hour operation)
•
Only requires 1 PCI slot
•
Transfer rates up to 150 MB/s
Primary Hard Disk (HDD 0)
Secondary Hard Disk (HDD 1)
HDD 0
HDD 1
SATA
RAID
Access LED (yellow) for primary (HDD 0)
and secondary hard disk (HDD 1)
Figure 57: PCI SATA RAID controller
Information:
The PCI SATA RAID controller cannot be used in place of a Universal Power Supply (UPS). If the oper-
ating system is shut down improperly, the next time it is started it is detected as an error by the RAID 1,
and a complete rebuild is executed. If 500 GB of memory are used, this generally takes approximately
500 minutes (configurable) to complete.
3.6.16.2 Order data
Model number
Short description
Figure
Drives
5ACPCI.RAIC-06
PCI RAID System SATA 2x 500 GByte; Hinweis: Beachten Sie
das Manual zum Einsatz der Harddisk.
Optional accessories
Drives
5MMHDD.0500-00
500 GB SATA hard disk replacement for 5AC801.HDDI-04,
5AC901.CHDD-01 and 5ACPCI.RAIC-06; Remark: Please see
manual for proper use of the hard disk.
Table 87: 5ACPCI.RAIC-06 - Order data