5.10 Eight Automation Panel 900 units via onboard SDL and SDL AP Link
Four Automation Panel 900 units (max. UXGA) are connected to the integrated SDL interface (onboard) via SDL.
Four additional Automation Panel 900 units (max. UXGA) are connected to the optional SDL transmitter (AP Link).
The Automation Panels in each line must be the same type. The two lines show different content (Extended Desk-
top), but panels in the same line show the same content (Display Clone).
USB is supported up to a maximum distance (SDL segment 1 + SDL segment 2) of 30m on the first two panels
(front and back side). From a distance of 30 m and longer, USB is only available for the first panel on each line.
USB devices can only be connected directly to the Automation Panel (without hub).
SDL Segment 1
Max. 40 meters
Link: 5DLSDL.1000-01
USB OK
Link: 5DLSDL.1000-01
USB OK
SDVO-C
SDVO-B
Internal device number on the APC
SDL Segment 1
Max. 40 m
Link: 5DLSDL.1000-01
USB
possible
Link: 5DLSDL.1000-01
No USB
possible
Link: 5DLSDL.1000-00
Link: 5DLSDL.1000-01
USB
possible
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-00
No USB
possible
No USB
possible
No USB
possible
SD
L
Se
gm
en
t 2
M
ax
. 4
0
m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SD
L
Se
gm
en
t 4
M
ax
. 4
0
m
SD
L
Se
gm
en
t 2
M
ax
. 4
0
m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SD
L
Se
gm
en
t 4
M
ax
. 4
0
m
AP Link
Connection
Monitor / Panel
Connection
Independent of segment length
Depends on segment length
Not supported
Automation PC 810
With AP Link
5AC801.SDL0-00
Figure 92: Eight Automation Panel 900 units via onboard SDL and SDL AP Link (sample photo)
5.10.1 Basic system requirements
The following table shows the possible combinations of APC810 system unit and CPU board to implement the
configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this is
also indicated (e.g. when connecting a non-B&R Automation Panel 900 device).
with system unit
CPU board
5PC810.SX01-00
1)
5PC810.SX02-00
5PC810.SX03-00
5PC810.SX05-00
Limitation
Resolution
5PC800.BM45-00
-
✓
✓
✓
Max. UXGA
5PC800.BM45-01
-
✓
✓
✓
Max. UXGA
Table 162: Possible combinations of system unit and CPU board
1)
AP Link cannot be installed.
5.10.2 Link modules
Information:
A corresponding link module must be selected for every device used.