2.6.10 Add-on UPS slot
An optional Automation PC add-on UPS module or the APC810 ready relay /2 can be installed in this slot.
Add-on UPS slot
Pinout with installed add-on UPS module
1
+
2
+
3
-
4
-
5
NTC (for battery temperature measurement)
6
NTC (for battery temperature measurement)
Model number
Short description
Uninterruptible power supply
5AC600.UPSI-00
Add-on UPS module
5AC600.UPSB-00
Battery unit 5 Ah
5CAUPS.0005-00
UPS cable 0.5 m
5CAUPS.0030-00
UPS cable 3 m
APC810 Ready relay
5AC801.RDYR-01
APC810 Ready relay /2
1 2 3 4 5 6
Table 27: Add-on UPS slot (with and without installed UPS)
For additional information about the UPS module, see Chapter 6 "Accessories", section 334.
2.6.11 AP Link slot
When connected with the 5AC801.SDL0-00 AP Link card, it is possible to implement a second graphics line with
DVI and SDL, but without RGB signals. In addition, the 5AC801.RDYR-00 ready relay can also be installed for
the APC810.
Information:
AP Link cards can only be installed with system units 5PC810.SX02-00, 5PC810.SX03-00 and
5PC810.SX05-00.