Technical data • Individual components
Chapter 2
Technical data
Automation PC 810 with GM45 CPU board user's manual V1.28
161
3.8.2 5AC801.RDYR-00
3.8.2.1 General information
Information:
Installation of the ready relay is only possible in connection with the system units 5PC810.SX02-00,
5PC810.SX03-00 and 5PC810.SX05-00.
Figure 69: Mounting example with the system unit 5PC810.SX02-00
The relay contacts are closed when the APC810 is turned on.
3.8.2.2 Order data
Model number
Short description
Figure
Automation Panel Link interfaces
5AC801.RDYR-00
Ready relay for APC810
Required accessories
Terminal blocks
0TB704.9
Accessory terminal block, 4-pin, screw clamps 2.5 mm²
0TB704.91
Accessory terminal block, 4-pin, cage clamps 2.5 mm²
Table 111: 5AC801.RDYR-00 - Order data
3.8.2.3 Pinout
Ready relay - Pinout
Pinout - 4-pin multipoint plug
N.O. and N.C., max. 30 VDC, max. 10 A
Pin
Assignment
1
Normally open contact
2
Root
3
Normally closed contact
4
NC
1
4
Table 112: Pinout - Ready relay 5AC801.RDYR-00