– Must be performed by a technician –
– Must be performed by a technician –
129
Service
8B. Service
Test Mode
Troubleshooting
Disconnect the connector, remove the four bolts and replace the bill validator.
Connector
Bolt
To install, perform the procedure in reverse.
(b) Removing the bill validator box
* Perform this task to operate the machine without using the bill validator.
z
z
Perform this task before joining the front and rear assemblies.
Turn off the power switch. (See “8A-2-3 Turning the Power Switch On” on page 77.)
Use the coin door key to open the door, and remove the four flange socket bolts (M8 x 12)
from the inside of the coin box and the two flange socket bolts (M8 x 12) from inside the hole
on the side of the base.
Flange socket bolt (M8 x 12)
Flange socket bolt (M8 x 12)
Hole on the side
of the base