(11) Replacing the Control Lever Vibration Motor – Must be performed by a technician –
z
z
In order to avoid electric shock, accident or injury to yourself or others as well as damage to the
electronic circuits, be sure to turn off the power switch before starting this task.
Turn off the power switch. (See “8A-2-3 Turning the Power Switch On” on page 77.)
Remove the control lever assembly. (See “8B-5-1 (6) Replacing and Installing the Control
Lever Assembly” on page 103.)
Remove the button bolt (with spring washer) (M4 x 30) and two cap bolts (with spring washer)
(M3 x 30) and remove the motor cover.
Cap bolt (with spring washer)
(M3 x 30)
Button bolt
(with spring washer)
(M4 x 30)
Vibration motor
Motor cover
Disconnect the connector, remove the Phillips pan head screw (with flat and spring washers)
(M3 x 6) and remove the vibration motor, ferrite core and core spacer.
Vibration motor
Ferrite core
Phillips pan head screw
(with flat and spring
washers) (M3 x 6)
Core spacer
Connector