Installation on vertical pipe
CAUTION
Improper installation may result in leakage or damage to the pipe flanges.
Required accessories
The following parts are required:
Through-bolts and nuts
Centering guide bushings
Gaskets: The required gasket material will vary according to the material of the pipe
on which the detector is to be installed. See the installation proce- dures for
different pipe materials described on pages 2-17 to 2-22.
Procedure
Follow this procedure to install the detector on a vertical pipe.
Step
Action
Drawing
1
Of the flange holes shown by black dots in
the drawing, insert through-bolts into the
two holes at the back and fasten them
lightly with nuts. Slip one centering nut
onto each through bolt before inserting the
bolts.
Flange
Terminal
box side
Back
Centering nuts
2
Turn the detector so that the direction
mark on the detector matches the
direction of fluid flow.
Insert the detector and gaskets between the
pipe flanges.
Gasket
Direction
of fluid flow