3-6
Integral style
TIIS/KOSH
A Explosion-protected
Apparatus magnetic flowmeter
Hazardous area
Non-hazardous area
Pulse output
or
Status output
(Intrinsically
safe circuit)
Flameproof
cable gland
Flameproof
cable gland
Power supply /
Output
2-core
shielded cable
+
-
+
-
+
-
E
E
Status output
or pulse output
receiver
General
equipment
H
(+)
N
(-)
or
Integral style
TIIS/KOSHA
Explosion-protected
Apparatus magnetic flowmeter
Hazardous area
Non-hazardous area
Pulse output
Status output
(Intrinsically
safe circuit)
Flameproof
cable gland
Flameproof
cable gland
Power supply /
Output
3-core
shielded cable
+
-
+
-
+
E
E
Status output
or pulse output
receiver
General
equipment
H
(+)
N
(-)
-
Fig. 3-5. Installation method of TIIS/KOSHA Intrinsically Safe
CAUTION
In accordance with the safety standards of flameproof regulation, please comply with the
following instructions:
1. The voltage of general equipment such as the power supply and the receiver should not
exceed 250 V AC, 50/60 Hz, 250 V DC at any time at normal or abnormal operation.
2. 1) The ambient temperature around Magnetic Flowmeter is max.50°C (122°F).
2) The fluid temperature is 125°C (257°F) max. (The line size 10 mm (3/8 inch) or less
is 100°C (212°F).)
3) Please use specified flameproof cable gland adaptors.
4) Please do not open the case cover during operation.
5) Please wait for seven minutes after switching OFF the power supply, before opening
the front cover or side terminal cover.
3. A specified explosion-proof performance is available only when this electromagnetic flow
meter is used according to the described specification.
Summary of Contents for MagneW Two-wire PLUS+ MTG15A
Page 8: ...vi...
Page 22: ...1 14...
Page 56: ...2 34...
Page 60: ...3 4 Fig 3 2...
Page 66: ...3 10...
Page 70: ...4 4...
Page 144: ...5 74...
Page 226: ...6 82...
Page 268: ...7 42...
Page 274: ...8 6...
Page 275: ......
Page 278: ......
Page 280: ......