2-10
CAUTION
Before installing the detector make sure that the pipe is exactly straight and centered. Any
irregularity in these respects could cause leakage or other hazards.
Tilted pipe
Off center
Fig. 2-7. Examples of unacceptable installations (1)
Note) Never force the device between two flanges when the space is too narrow. It can damage
the detector.
Fig. 2-8. Examples of unacceptable installations (2)
WARNING
Ensure the bore diameters of the pipe and the detector are exactly the same, install the
detector so that the gasket does not protrude into the internal bore of the pipe, as this could
result in leakage or other hazards.
Note) Tighten each bolt a little at a time and apply uniform torque to all the bolts while
fastening them. If leakage does not stop on completion of fastening, make sure that the
pipe is not off center, then tighten the bolts little by little. Install the detector carefully so
that the fastening torque does not exceed the prescribed limit; otherwise the detector could
be damaged.