6-45
Step
Key
Procedure
SFC screen
6
ENTER
( Yes )
NON-VOL
Press the
ENTER
( Yes )
NON-VOL
key.
Result:
The screen as shown on the right
appears and the set low flow cutoff is
confirmed.
SFCM00006051D
7
H
NEXT
or
L
PREV
Press the
H
NEXT
key or
L
PREV
key to
show this screen (DOWN LOAD).
SFCM00006053D
8
ENTER
( Yes )
NON-VOL
Press the
ENTER
( Yes )
NON-VOL
key.
Result:
The screen as shown on the right
appears and the changed setting is
written into the database of the
converter. The screen returns to step
2.
Note)
In step 5, if you try to set displaying “CUT
OFF = OFF” or “CUT OFF = ON 00%”,
“INVALID REQUEST” will appear on the
screen. Converter will reject the database
to be written in.
SFCM00006054D
SFCM00006055D
9
SHIFT
+
CLR
( No )
To exit this setting function, press the
SHIFT
+
CLR
( No )
keys.
10
ENTER
( Yes )
NON-VOL
Press the
ENTER
( Yes )
NON-VOL
key.
Result:
Exiting the low flow cutoff setting
function, the screen returns to the
screen in step 1.