1 – 2 8
040 7448 329657 (04.97) PC-SW 4.5
C H A P T E R 1 : S Y S T E M D E S C R I P T I O N
1.5.5.3
RS485 bus interface
The RS-485 interface is a bus interface to connect several codecs in a chain.
This makes it possible to control several codecs from a PC.
1.5.5.4
TTL interface
The operator interface is compatible with the parallel interface of a PC or prin-
ter. A log printer can thus be connected without the need for adaptation.
The interface can also be used to control external equipment. There are 10
outputs, 5 inputs, 8 programmable inputs/outputs, GND and +5V.
Plug: RS-485 (SUB-D 9pole)
Connect.
Signal
Electrical characteristics
1
SHIELD
Type:
Bus
Level:
V.11, symmetrical
Data rate:
300 to 19200 Baud
Range:
100 m
2
DATA A
3
CONTROL A
4
not connected
5
GND
6
DATA B
7
CONTROL B
8
not connected
9
not connected
Summary of Contents for Titan
Page 1: ...TITAN Videocodec ISDN Videocodec Operator Manual ...
Page 2: ...T I T A N V I D E O C O D E C I S D N V I D E O C O D E C O P E R A T O R M A N U A L ...
Page 7: ...040 7448 329657 04 97 PC SW 4 5 ...
Page 147: ...8 153 040 7448 329657 04 97 PC SW 4 5 C H A P T E R 8 F A C T O R Y S E T T I N G S ...