3 – 9 0
040 7448 329657 (04.97) PC-SW 4.5
C H A P T E R 3 : O P E R A T I O N W I T H A P C
3.3.10
SYSTEM Panel
Monitoring and control of the system can be undertaken from the SYSTEM pa-
nel. Here, alarm messages are displayed, commands (see CHAPTER 5) can
be entered, and self-tests can be activated. This panel is called up by clicking
SYS! in the menu bar.
3.3.10.1
Command entry
After the window has been activated with the cursor, commands can be en-
tered to control the codec. These commands are similar to the ones listed in
CHAPTER 5. “^B” in front of the command word can be left out. The codec’s
response is output in the SYSTEM RESPONSE window.
The password that you obtain when the range of codec functions is extended
can also be entered in the COMMAND field. To enter the password, type in
PASSWD followed by a space and the new password.
To obtain an overview of the allowable commands and the syntax, enter the
command “help”. A complete list is output in the SYSTEM RESPONSE field.
3.3.10.2
LOG FILE
Commands, system responses and alarms can be recorded automatically in
a log file (LOG.PRT in the current directory). This selector switches this
function on or off.