VENUE SC48 Guide
58
Interaction
The Interaction page lets you configure behaviors for the Se-
lected Channel (ACS) sections, Input Safe Switches, Lights,
Meter, Ethernet, and LCD Display.
Assignable Channel Selection
Options in this section set the mechanism by which channels
are targeted on the Selected Chan sections (also known as the
ACS, or Assignable Channel Section).
On the VENUE SC48 this setting can also affect the Channel
Control section and the Flex Channel.
To customize console and screen interaction:
1
Go to the Options page and click the
Interaction
tab.
2
Set the following Assignable Channel Selection options:
Change Target By
The Change Target By options let you specify whether the fol-
lowing actions target a channel on the ACS. More than one
option can be selected simultaneously.
• Touching Input Faders
• Engaging Input Solos
• Touching Output Faders
• Engaging Output Solos
Targeting Changes View Mode
The Targeting Changes View Mode option updates the
on-screen display to show the page for the channel targeted.
When this option is deselected, the on-screen display does not
update when a channel is targeted.
Meter
Metering settings provide the following options for meter bal-
listics, peak, and clip indication.
Ballistics
This option lets you choose RMS or Peak ballistics
for the control surface and on-screen meters.
Input Clip Margin and Output Clip Margin
These options set the
level, relative to the maximum (full scale) level, at which a clip
is reported on a channel. When a clip is detected, the entire
channel meter turns red.
To set Input or Output clip margin:
1
Click in the
dB Below Max
edit box for Input Clip Margin or
Output Clip Margin.
2
Enter a value or drag to change the value and press Enter.
The entered value is interpreted as a relative dB value from the
maximum (where “Max” is cons20 dBVU). For exam-
ple, with the Input Clip Margin set to 6 dB below max (the de-
fault), peak levels within 6 dB of maximum level will trigger a
clip indication
Clip Hold Time and Peak Hold Time
These options specify how
long clips and peaks are held. Default is 2 seconds for both
Clip and Peak hold.
Input Safe Switches
The Input Safe Switches let you control two independent Safe
functions: Automation Safe and Solo Safe. Only one of these
Safe functions can be viewed and controlled at a time.
Act as Automation Safes
When selected, this option sets the
console Safe switches and on-screen channel Safe buttons to
toggle the Automation Safe status of the corresponding chan-
nel. For more information, see Chapter 21, “Snapshots.”
Act as Solo Safes
Solo Safe applies only to Input Channels
and FX Returns. When selected, this option sets the Safe
switches to toggle the Solo Safe status of the corresponding
channel. See “Solo Bus Operation” on page 113.
Act as Bank Safes
When selected, this option sets the Safe
switches of Input Channels and FX Returns to toggle that
channel’s Bank Safe Status. (Bank Safe keeps channels at the
top fader layer, immune to input banking.) For more informa-
tion, see “Bank Safe Mode for Input Safe Switches” on page 34.
Ethernet Control
Ethernet Control settings let you configure ECx Ethernet Con-
trol for remote control of the VENUE system over a wireless
Ethernet network.
Interaction tab of the Options page
VENUE SC48 also provides the latchable Flex Channel. For
more information, see “Flex Channel” on page 71
For more information, see Chapter 31, “ECx.”