4.2.4.
Blower control board
NOTES:
-
During the installation it’s necessary to respect the
correct connection of phase and neutral (non
inverted). If the connection is inverted the
microAmpere reading of the flame detector will be
lower as it should be.
-
On the level 3 models the microAmpere reading
can be displayed. It is possible to activate this
function from the Service menu; the reading needs
to be divided by 10 (e.g. 32 / 10 = 3,2
microAmpere).