2.3. Drain cooldown / steam condensing operation
The inlet water assembly 11 feeds the cooling water injector 12. The opening of the water
solenoid valve is timed based on the mode of operation (convection, combi or steam),
chamber temperature and the temperature detected by temperature sensor 9.
The inlet water assembly 11
is different depending on the levels:
Level 3
It consists of:
- Back flow preventer (non return valve) EN1717 (for washing)
- Pressure reducer (for washing)
- Double water solenoid valve (one is for washing)
- Pressure switch on the drain cooldown line
- Pressure switch and manometer on the washing water line
Note: the water pressure adjustment should be done during a washing cycle.
Level 2
It consists of:
- Double water solenoid valve (one is for cleaning)
- Pressure switch on the drain cooldown line
- Pressure switch on the washing water line
- Pressure reducer (only models FX201-202)
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...