Copyright by Servizio Clienti ANGELO PO Spa
86
Problems during the "CLEAN TEST"
6
-
During phase 1 the detergent pump
doesn’t work. (the motor doesn’t
turn).
Check pump wiring. Check voltage on pole 68 on
power board.. Check fuse F1.Check power supply on
pump cables. Chamber temperature must be under
100°C.
7
-
During phase 1 the detergent pump
works but the tank is not filled on
time.
Check the pipe position and the level of cleaner in the
tank. Check if there is a leakage on the piping. If
previous check are OK, replace the pump inner tube or
the whole pump.
8
During phase 1 the detergent pump
works but the float doesn’t switch.
Wait until the tank is filled until at least half. Check the
wiring of the float (inputs 81 and 82 on power board).
Unplug the connector and check that the resistance of
the float (with the tank above half) must be in short.
Replace the float.
9
-
During phase 2 the sanitizer pump
doesn’t work. (the motor doesn’t
turn).
Check pump wiring. Check voltage on pole 66 on
power board.. Check fuse F1.Check power supply on
pump cables. Chamber temperature must be under
100°C.
10
-
During phase 2 the sanitizer pump
works but the tank is not filled on
time.
Check the pipe position and the level of cleaner in the
tank. Check if there is a leakage on the piping. If
previous check are OK, replace the pump inner tube or
the whole pump.
11
-
During phase 2 the sanitizer pump
works but the float doesn’t switch.
See point 9
12
-
During phase 3 the water doesn’t fill
the tank.
Check the pressure of water supply, control the power
supply rinse solenoid (terminal 17 on the power board),
check fuse F5, check the pressure regulator. Replace
the solenoid.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...