5. Now you are into the setup wizard: Step 1:
-
check correct ignition
-
Verify the stability of the minimum power
-
Check combustion values (CO,CO2) with oven cold
-
Fill in the installation report with the values found
6. Step 2:
-
Verify the stability of the maximum power
-
Check combustion values (CO,CO2) at maximum
power
-
Fill in the installation report with the values found
7. Step 3:
-
Verify the correct ignition
-
Verify the stability of the minimum power with the oven
warm
-
combustion values (CO,CO2) at minimum power with
the oven warm
-
Fill in the installation report with the values found
For the flue gases analysis see section 4.6. Combustion
products analysis.
The screen shows the parameters that govern the blower (Minimum speed, Maximum
Speed, Ignition Speed), in addition to the speed to be achieved (set point) and the actual
speed. Verify that the ignition occurs at the correct speed and that the minimum and
maximum speeds reached match those settings.
If the gas system doesn’t function properly or the flue combustion values are not included
in the ranges indicated, follow the instructions in section 4.4.3 Adjustments.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...