Copyright by Servizio Clienti ANGELO PO Spa
12
2.2. Closed valve operation
With the valve closed, the steam can not escape from the vent pipe 6, or from the tube 5 at
least until the pressure inside the cooking chamber is not sufficient to overcome the effect
of decompression generated by the rotation of the fan (usually 1,5-2,0 mBar). But when the
pressure chamber exceeds the decompression generated by the fan, the steam excess is
expelled through the tube 5. The system operates as a closed system, where the
overpressure valve (overpressure valve in the FM ovens) is dynamically replaced by the
effect of decompression generated by the fan. Even in this mode, water is sprayed by the
injector 12 in order to maintain the siphon full.
Note that, unlike than the FM, the condensate tube 14 is connected upstream of the swing
of the siphon, as with the motorised valve closed the vent pipe 6 and the drain tube 14 are
at the same pressure of the cooking chamber.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...