Copyright by Servizio Clienti ANGELO PO Spa
26
- Enter the service menu
- Select " Update parameters "
- Enter the password “FA53”
- Wait until the end of the procedure and follow the instructions that appear on the
display
When the procedure has finished, turn off and on the oven as written on the display.
Oven Number: identification number of the oven within a network of ovens. It is used
during HACCP data download as not to create conflicts within the network and to uniquely
identify the data from each appliance.
Testing APGC: this choice is subject to Password and is used only at the end of the test
cycle into the factory before the oven is shipped to the final customers.
Display gas: allows visual check, during normal operation of the machine, the parameters
and the states of the gas unit. It must be repeated each time the machine is switched on.
Gas setup: this option allows you to enter into the gas setup, the password is SI74.
RH% Calibration: This selection allows you to activate the calibration procedure of the UR
probe (humidity probe). The procedure takes about 10 minutes to run. The procedure is
performed with the oven cold and finish with the oven at 230 ° C. This procedure should
be performed every time you replace the UR probe or whenever you replace the
power board (2).
Clean test: See chapter 6.3.
Pump unit selection: set 0 if is installed the black/brown pumps unit, set 1 if is installed
the blue pumps (first version).
T/RH display: This option is for internal use of Angelo Po
.
Counters: displays the numbers of washing programs performed and the working times at
low and high temperature.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...