7.11. Lock dismantling 20 trays models
To replace the lock, follow the instruction below:
1. remove the cap of the handle using a thin screwdriver ( picture 1);
2. unscrew the handle securing screw (picture 2);
3. disassemble the handle from its seat (picture 3)
4. remove the blocking lock by unscrewing the three screws on the door (picture 4);
5. pay attention to the washers on lock of the handle (picture 5);
6. Unscrew the screw rear handle lock for its removal (picture 6);
7. to access the lock assembly (picture 7) remove the panel behind the lock (picture
8);
PICTURE 4
PICTURE 3
PICTURE 2
PICTURE 1