The detergent and sanitizing distribution is made as follows:
•
Product load. The pump sends the chemicals into the empty tank, this phase takes a
few minutes. The total amount of chemicals is less than the tank capacity.
•
Distribution. After stopping the pump, the water solenoid valve opens for a few seconds.
The water pressure (1.5 bar nominal Max 2 bar) passes through the tank and mixed
with the product, carries it into the chamber through the appropriate sprinklers.
•
Emptying the tank. After finishing the distribution, the tank, still full of water and residual
chemical, is flushed through the solenoid valve until the next stage.
Rinsing is accomplished by operating the solenoid water for several minutes. The water
circulates through the tank and the dispensing circuit, and finally is distributed in the
chamber through the sprinklers.
The circuit is also fitted the following safety:
•
Water pressure switch: it is downstream of the solenoid water and detects the presence
of pressure in all the phases in which the water valve is open (or supply rinsing
detergent / sanitizer).
•
Level sensor: it is a float sensor located inside the tank. It checks the chemicals
loading and the emptying phases of the tank. During loading, if the level sensor doesn’t
switch, after a predetermined time, the display shows alarm (E21 or E22). During the
emptying phase of the tank, after a fixed time the display, if the level sensor doesn’t
switch, shows an alarm (alarm E24).
NOTE:
- Since version 2.xx each time you switch on the oven, it runs for 5 seconds the dosing
pumps, then it opens for 0.5 seconds the rinsing solenoid valve and then it empties the
tank for 20 seconds.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...