Change the parameters of the combustion control board
This adjustment must be done only and exclusively upon contact with
Service Angelo Po.
The wizard test (see section 4.4.1), In the "Step 2" and "Step 3", activate
the button "Modify Parameters".
By clicking the button it is possible to change the parameters that govern the blower speed:
- Maximum speed
- Minimum speed
- Ignition blower speed
- Acceleration
Select the parameter you want to change and set a different value depending on the
problem (see next paragraph).
Attention: never increase the maximum blower speed over the value set by the
factory.