Copyright by Servizio Clienti ANGELO PO Spa
28
3.3. Explanation table
When a component is replaced must perform the procedures indicated below - attention:
these procedures should be performed after replacement of the component and in the
order listed below.
ITEM REPLACED
PROCEDURES TO FOLLOW
CPU board (1a)
Update parameters
Configure oven type
Gas setup
Display LCD board (1b)
None
LED board (1d)
None
Power board (2)
Update parameters
Configure oven type
RH calibration (humidity probe)
Combustion and blower
control PCB (3)
Configure oven type
Inverter (4)
Configure oven type
USB connector (5)
None
Note: After replacing one of the items listed above, at the first ignition of the oven you may
see alarms E13 and / or E20. After following the procedures listed in the table the alarms
should no longer appear.