Modulation Transitional power: the system is able to control all the range of power
from minimum to maximum with the control of the rotation speed of the blower fan
by the power board. In this way the combustion is "good" at any range of power.
•
Minimum power: The minimum power is set at 30-40% of maximum. In this case,
the vacuum created by the blower decreases and the effect of the valve offset
adjusting becomes more important. The proper adjustment of the valve is essential.
For details concerning the valve adjustment, see the section 4.4.3. Valve offset
adjusting.
* With the PLUS function turned off the oven works with maximum set at 90% of maximum
power, to use 100% of the power it is necessary to enable the PLUS function.
NOTE:
- The burner ignition occurs at a power of about 10% higher than the minimum (40-50%).