Copyright by Servizio Clienti ANGELO PO Spa
11
The system works in two distinct ways depending on whether the motorised valve is
opened or closed.
2.1. Open valve operation
The rotation of the fan creates a vacuum effect in the local area behind his disk back where
it faces the suction pipe/exhaust 5. When the butterfly valve 7 is open to this effect a
vacuum sucking air flow entering through the pipe 5. Simultaneously the moist air inside
the cooking chamber is induced to leave through the vent tube 6, aided by a flow diverter
(not shown) placed inside the chamber at the exit hole. Through the injector 12 is sprayed
water into the vent pipe - especially at high temperatures - in order to cool and condense
the flow of moist air coming out. The condensate is collected on the bottom of the pipe to
siphon 6 and conveyed through the rubber hose 14.