Copyright by Servizio Clienti ANGELO PO Spa
64
4.4.3.
Adjustment during the test
Values of the minimum ignition failure: Offset Adjust gas valve (PR.ADJ.)
If the combustion values at minimum power do not
correspond to the recommended offset adjusting of
the valve is needed.
To do this with a screwdriver unscrew the protective
brass cap and take a 4mm Allen wrench.
At this point, if the CO2 is lower than the
recommended value, screw clockwise (see figure at
right), to enrich the mixture.
If the CO2 is higher unscrew slowly to lessen the
mixture.
The adjustment is very sensitive and you should make
small movements (a quarter turn rotation involves a variation of about 1% CO2) and wait
for the gas analyzer to detect the change and stabilize.
Once done repeat the wizard test.
When the adjustment is finished refit the protective cap of the screw.
Attention: the pressure adjustment screw PR.ADJ. has no effect on
increasing the power of the oven.
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...