Copyright by Servizio Clienti ANGELO PO Spa
45
4.2. System components
The picture shows all the components of the gas system.
Attention:
- Always check before every intervention that all components are securely attached
(electrical connectors, screws, clamps, fittings, insulation materials ..)
- Be sure the air inlet filter (9) and the exit of the gas valve pressure test point pipe
(6) are totally clean (if necessary clean them properly).
- As the gas inside the tube (7) and the fitting (3) is at negative pressure, in case of
leak to find it don’t use flame because it could be sucked in the mixer and cause a
fire / explosion.
14 - BLOWER CONTROL BOARD
15 - COMBUSTION CONTROL BOARD
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...