Copyright by Servizio Clienti ANGELO PO Spa
125
Alarm on
display
Problem (on
the manual)
Solution (on the
manual)
Note (on the
manual)
Note for Service
E29
Core probe not
inserted
Press reset button
The oven’s
functions are
enabled so
cooking
cycles can be
carried out.
---
E30 – E38
Electronic circuit
board
diagnostics
tripped.
Press reset button
If the problem
persists
inform the
after-sales
service.
Protections against electromagnetic
interferences. Check all the ground
wiring of the equipment. In case of gas
version, please check ignition electrode
and cover protections to be properly
fitted. Check all the wirings relative to
the ignition system. Check the correct
insulation of the cable.
E80 – E85
---
---
Inform the
after-sales
service.
---