Copyright by Servizio Clienti ANGELO PO Spa
74
4.9. Gas conversion
All equipment is tested and adjusted to work with Natural gas (G20), where it is required to
use a propane gas, follow the instruction below:
1. Gas nozzle replacement: Unscrew the gas pipe (Photo 1), remove the Natural gas
(G20) nozzle and put in place the replacement nozzle (photo 2), then tighten the
pipe. The nozzle works also as seal.
The nozzle must be mounted as shown in photo 3.
Injectors
FX61G3
FX101G3
FX82G3
G20
Ø635 - 3147120
Ø605 - 3141800
Ø635 - 3147120
G31
Ø465 - 3141630
Ø485 - 3153010
Ø485 - 3153010
Injectors
FX122G3
FX201G3
FX202G3
G20
Ø640 - 3147130
Ø640 - 3147130
Ø615 - 3141820
G31
Ø500 - 3167720
Ø465 - 3141630
Ø480 - 3153000
2. Setting the type of gas on the display:
o
enter menu “Service” (Password:SAAP),
o
enter menu “Setup gas”(Password:SI74),
o
select the type of gas used from the menu “Type of gas”
3. Perform analysis of flue gas (see section 4.6)
PICTURE 1
PICTURE 2
PICTURE 3
Summary of Contents for FX Series
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa 1 Rev 1 LEVEL 1 and 2 LEVEL 3 LEVEL 2 ...
Page 4: ...Copyright by Servizio Clienti ANGELO PO Spa 4 1 COMMERCIAL MODEL NUMBER 2 3 ...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 OVEN CONNECTION DIAGRAM FX122G3 ...
Page 34: ...Copyright by Servizio Clienti ANGELO PO Spa 34 1a CPU board 1b Keyboard ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Functional diagram gas system ...
Page 106: ...Copyright by Servizio Clienti ANGELO PO Spa 106 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 117: ...Copyright by Servizio Clienti ANGELO PO Spa 117 7 16 Roll In adjustment RX201 RX202 ...
Page 118: ...Copyright by Servizio Clienti ANGELO PO Spa 118 ...