Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-52
Entry
Description
Latching
When the contact is opened between remote inhibit terminal and
return, output is turned off and programmed to zero volts and the
output latches in shutdown state.
Having configure the channel remote inhibit input to Latching mode
and contact opening in the remote inhibit input of channel creates
remote inhibit fault in the front panel, user need to clear the fault to
come out of the latched state. The fault needs to be cleared from the
front panel fault status popup window or by issuing the SCPI
Command OUTP<n>:PROT:CLE from the remote digital interface.
Once the fault is cleared, power supply output is unlatched, upon the
contact closure user can turn on the output of the power supply.
Live
When the contact is opened between remote inhibit terminal and
return, output is turned off and programmed to zero volt.
Having open contact between remote inhibit and return will shut down
the output or will not allow the user to enable the output of the power
supply and a contact between remote inhibit terminal and return will
permits user to enable the output.
In the live mode no fault is generated, and the output is not latched.
3.4.6.3
U
SER
V/I
L
IMITS
The User V/I Limits menu allows to set the soft limits for output voltage, current and
power to each channel at power supply restart. Default values are PONS User V/I
Limits configuration, refer to Figure 3-44.
Up-Arrow and Home button will return to HOME MENU screen 2; Refer Figure 3-14.
Figure 3-44: User V/I Limit Screen
– Channel 1
Figure 3-45: User V/I Limit Screen
– Channel 2