Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-62
PONS - Configure Reference Source:
Sets the analog reference source to either Voltage or Resistive during supply power-
ON for Selected channel, Refer Figure 3-70.
Figure 3-70: PONS
– Configure Reference Source channel - 1
Entry
Description
Voltage
Configures power-on analog programming reference source as voltage
source for selected channel. Voltage is the factory default reference
source. For a given channel reference source would be same for both
output voltage and output current analog programming.
Resistive
Configures power-on analog programming reference source as
resistance for selected channel
.
For a given channel reference source
would be same for both output voltage and output current analog
programming.
PONS - Configure Full Scale Value:
Sets the analog programming Full Scale Value (FSC) of Analog Voltage and Current
programming for Selected channels at power-ON, Refer Figure 3-71 and Figure 3-72.
If the PONS -analog ref source is selected resistive the unit of FSC would be
kΩ (Kilo
Ohm); refer Figure 3-72, and if it is voltage the unit of FSC will become V (volt); refer
Figure 3-71.
Figure 3-71: PONS
– Configure Full Scale Value Channel-1