Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-84
Figure 3-121: Configure Reference Source
– Channel 2
Figure 3-122: Configure Reference Source
– Channel 3
Entry
Description
Voltage
Configures analog programming reference source as voltage source
for selected channels. Voltage is the factory default reference source.
Resistive
Configures analog programming reference source as resistance for
selected channel.
3.4.9.3.3
Configure Full Scale Value
Sets the analog programming Full Scale Value (FSC) of Voltage and Current
programming for Selected channels, Refer Figure 3-124. default FSC value for both
analog voltage and current programming is PONS
– Configure Full Scale Value.
Full Scale for Voltage parameter field box will be inactive (refer Figure 3-123) if analog
voltage ref mode is set to INT (internal).
Full Scale for Current parameter field box will be inactive (refer Figure 3-126) if analog
current ref mode current is set to INT.
Full Scale for Voltage parameter field box will be active (refer Figure 3-126) if analog
voltage ref mode is set to EXT (external) or INT + EXT (in external).
Full Scale for Current parameter field box will be active (refer Figure 3-126) if analog
current ref mode is set to EXT (external) or INT + EXT (in external).
If configure ref source is selected as resistive of selected channel the respective
channel unit of FSC value will become to
kΩ (Kilo Ohms) and if voltage is selected as
configure ref source (refer to Figure 3-121.) of selected channel the respective channel
unit of FSC value will become to V (volts) refer to Figure 3-125.