Asterion DC Multioutput ASA Series Operational Manual
M330516-01
2-10
2.8.2
AC Input Safety Disconnect Device
The Multioutput Asterion DC Series power source front panel POWER switch does not
disconnect the AC input line from the unit. Ensure that an appropriately rated safety
disconnect device is incorporated in the installation that will provide isolation from the
AC input when the device is opened. The device could be a switch or circuit breaker,
and must be located close to the unit, within reach of the operator, and clearly labeled
as the disconnection device.
2.8.3
AC Input Connector
The AC input connector, AC INPUT, is located on the rear panel, along with the safety-
ground stud. Figure 2-5 shows the rear panel view of the connector and stud. Table
2-4 shows the functions and connector pinout, and Table 2-5 lists the connector type.
Figure 2-5: AC Input Connector and Safety-Ground Stud
Figure 2-6: AC Input Connector wiring