Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-57
PONS menu contains following sub menu:
•
PONS
– Output Settings
•
PONS
– Output State
•
PONS
– Regulation Mode
•
PONS
– User V/I Limits
•
PONS
– Voltage Reference Mode
•
PONS
– Current Reference Mode
•
PONS
– Analog
•
PONS
– Measurement Settings
•
PONS
– Remote Inhibit
3.4.6.7.1
PONS - Output Settings Screen
The PONS Output Settings screen provides output related settings such as Voltage,
Current and Over voltage Protection (OVP) for each channel during unit power-on.
Settings set in below screen will be applied during next power cycle of unit.
Figure 3-58: PONS - Output Settings Screen
The following choices are available in the PONS Output Settings screen. Functions
that accept a numeric value require that the value be within the allowed range,
otherwise, an error will be generated, and the value will not be accepted.
Entry
Description
Voltage
Programs the power-ON output voltage in Volts for each channel. The
default value of each channel is 0.
Current
Programs the power-ON output current in Amperes for each channel.
The default value for each channel is 0.
OVP
Programs the power-ON Overvoltage Protection (OVP) threshold for
the output voltage. Exceeding the OVP threshold will result in shutdown
of the output and the output voltage programmed to zero.
3.4.6.7.2
PONS - Output State Screen
PONS Output state screen provides the functionality to turn Output of each channel
either ON or OFF at power-on of unit. If output is set to ON for any channel, then during
next power cycle, warning screen will be displayed with abort button to turn off output