Asterion DC Multioutput ASA Series Operational Manual
M330516-01
1-9
1.2.3
Resolution Specifications
Resolution
Remote digital
Interface
Front panel
Voltage Output programming resolution
0.012% of full scale
4 Digits
Current Output programming resolution
0.012% of full scale
4 Digits
Power Output programming resolution
0.012% of full scale
4 Digits
Overvoltage programming resolution
0.1% of full scale
4 Digits
Voltage Output Readback resolution
0.012% of full scale
5 Digits
Current Output Readback resolution
0.012% of full scale
5 Digits
Power Output Readback resolution
0.012% of full scale
5 Digits
1.2.4
Remote Sense
Each channel is provided with sense terminals to sense voltage at the point of
connection to the load. Line drop in the wires would be compensated by remote
sense feature.
Output Voltage
Models
Allowed Line drop Voltage
40 V
2 V
60 V
3 V
80 V
– 400 V
5 V
Connection
Voltage accuracy specifications apply at the point where the remote sense leads
are connected
Line Drop Effect on
Output
There would be increased voltage equivalent to the line drop voltage at the
terminals of the Power Supply.
CAUTION!
Due to Line Drop Compensation, if Remote Sense is disconnected from
unit while the output is enabled, output voltage will rise a maximum of 10%
of model’s maximum rated voltage, before faulting.
1.2.5
DC
Output
Programming,
Readback
and
Regulation
Specifications
(1)(2)
Programming & Measurement Accuracy (via Front Panel or Remote Digital
Interface)
Voltage Output programming accuracy
+/- 0.1% of rated output voltage
Current Output programming accuracy
+/- 0.2% of rated output current
Power Output programming accuracy
+/- 0.3% of rated output power
Overvoltage programming accuracy
+/- 1%, maximum, of rated output voltage
Voltage Output Readback accuracy
+/- 0.1% of rated output voltage
Current Output Readback accuracy
+/- 0.2% of rated output current
Power Output Readback accuracy
+/- 0.3% of rated output power
Overvoltage Response time
20 ms